January 1, 2002 20 Lit. No. 13648/9511
TROUBLESHOOTING GUIDE
VARIABLE SPEED (PWM) CONTROL TROUBLE SHOOTING GUIDE
CONDITION
Left (Red)
Light
Right (Green)
Light
PROBLEM EXPLANATION / POSSIBLE SOLUTIONS
OFF OFF
Spinner does
not turn
No power to the cab control:
Turn the ignition switch on.
Turn the cab control on.
Check for power to the cab control.
OFF ON
Spinner does
not turn
If the motor is turning:
Disconnect the power
Remove the belt cover. Check for a broken belt or a
loose idler pulley.
If the motor is not turning:
Set the cab control to full speed. Check for voltage at
the motor terminal.
If voltage is present, the problem is in the motor.
If no voltage is present, problem is in the harness or
the connections.
ON OFF
Spinner does
not turn
Overload condition is causing over-current protection to
activate:
Reset the cab control by turning the power switch to
OFF.
Depress START/BLAST switch.
If the problem continues:
Turn the power off at the cab control.
Disconnect the electrical plug at the spreader.
Try to manually turn the spinner.
If the shaft will not turn manually, clear spinner/shaft
of obstructions and lubricate the bearings.
If the shaft turns freely and the condition continues,
the problem is in the motor or the cab control.